Article Text

other Versions

Download PDFPDF
Comparison of Touhy and Quincke needles on intravascular injection rate in lumbar transforaminal epidural block: a randomized prospective trial
  1. Hyojung Soh,
  2. Yujin Jeong and
  3. Eung Don Kim
  1. Department of Anesthesiology and Pain Medicine, Daejeon St Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea (the Republic of)
  1. Correspondence to Dr Eung Don Kim, Department of Anesthesiology and Pain Medicine, Catholic University of Korea College of Medicine, 34943 Seoul, Korea (the Republic of); ehs99{at}catholic.ac.kr

Abstract

Background Transforaminal epidural steroid injection is widely used in clinical practice to effectively deliver injectate into the ventral epidural space. Complications associated with intravascular injection such as spinal cord infarction and paraplegia can occur during transforaminal epidural steroid injection. To improve the safety of the procedure, avoidance of intravascular injection is crucial, for which appropriate needle selection is important. The primary aim of this study was to compare intravascular injection rates during transforaminal epidural steroid injection between commonly used Quincke and Tuohy needles.

Method Two hundred and four transforaminal epidural steroid injection cases were randomly assigned to one of two needle groups (22-gage Quincke needle or 22-gage Tuohy needle). Intravascular injection was evaluated using digital subtraction angiography. Spread of contrast medium to the ventral and medial epidural spaces was evaluated. Procedure time was compared between the two needle types.

Results The overall incidence of intravascular injection was 7.8%. The rate of intravascular injection was significantly lower in the Tuohy needle group than the Quincke needle group (2.9% vs 12.7%, p=0.009). The ventral and medial epidural spread rates of the Tuohy needle group were 92.2% and 95.1%, respectively, significantly higher than those of the Quincke needle group. The procedure time was shorter in the Tuohy needle group than in the Quincke needle group (97.4 (19.3) seconds vs 117.8 (31.9) s; mean difference −20.40 (95% CI −34.35 to −6.45), p=0.005).

Conclusions In conclusion, Tuohy needles had a lower intravascular injection rate and higher medial and ventral epidural spreading rates than Quincke needles.

Trial registration number KCT0002095.

  • nerve block
  • injections
  • spinal
  • postoperative complications

Data availability statement

Data are available on reasonable request. Since the patient’s information is included, it will be provided only when there is a reasonable request.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Data availability statement

Data are available on reasonable request. Since the patient’s information is included, it will be provided only when there is a reasonable request.

View Full Text

Footnotes

  • Contributors EDK and HS conceived the idea for this study; designed, planned the data collection; and participated in the data analysis, interpretation and manuscript writing. Y J Jeong participated in data collection for this study, data analysis, reporting and review of the manuscript.

  • Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.

  • Competing interests None declared.

  • Provenance and peer review Not commissioned; externally peer reviewed.