Validation of the soft-embalmed Thiel cadaver as a high-fidelity simulator of pressure during targeted nerve injection

Abstract

Introduction Although administration of regional anesthesia nerve blocks has increased during the COVID-19 pandemic, training opportunities in regional anesthesia have reduced. Simulation training may enhance skills, but simulators must be accurate enough for trainees to engage in a realistic way—for example, detection of excessive injection pressure. The soft-embalmed Thiel cadaver is a life-like, durable simulator that is used for dedicated practice and mastery learning training in regional anesthesia. We hypothesized that injection opening pressure in perineural tissue, at epineurium and in subepineurium were similar to opening pressures measured in experimental animals, fresh frozen cadavers, glycol soft-fix cadavers and patients.

Methods We systematically reviewed historical data, then conducted three validation studies delivering a 0.5 mL hydrolocation bolus of embalming fluid and recording injection pressure. First, we delivered the bolus at 12 mL/min at epimysium, perineural tissue, epineurium and in subepineurium at 48 peripheral nerve sites on three cadavers. Second, we delivered the bolus at using three infusion rates: 1 mL/min, 6 mL/min and 12 mL/min on epineurium at 70 peripheral nerve sites on five cadavers. Third, we repeated three injections (12 mL/min) at 24 epineural sites over the median and sciatic nerves of three cadavers.

Results Mean (95%) injection pressure was greater at epineurium compared with subepineurium (geometric ratio 1.2 (95% CI: 0.9 to 1.6)), p=0.04, and perineural tissue (geometric ratio 5.1 (95% CI: 3.7 to 7.0)), p<0.0001. Mean (95%) injection pressure was greater at 12 mL/min compared with 1 mL/min (geometric ratio 1.6 (95% CI: 1.2 to 2.1), p=0.005). Pressure measurements were similar in study 3 (p>0.05 for all comparisons).

Discussion We conclude that the soft-embalmed Thiel cadaver is a realistic simulator of injection opening pressure.

  • technology
  • education
  • patient simulation

Data availability statement

All data relevant to the study are included in the article or uploaded as supplementary information. Data are available from GML on request at g.a.mcleod@dundee.ac.uk.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.