Article Text

other Versions

Download PDFPDF
Cervical erector spinae plane block: a cadaver study
  1. Hesham Elsharkawy1,
  2. Ilker Ince2,
  3. Hassan Hamadnalla3,
  4. Richard L Drake4 and
  5. Ban C H Tsui5
  1. 1Department of Anesthesiology, Cleveland Clinic, Cleveland, Ohio, USA
  2. 2Department of Anesthesiology and Reanimation, Ataturk University, Medical School, Erzurum, Turkey
  3. 3Department of Outcomes Research, Anesthesiology Institute, Cleveland Clinic, Cleveland, Ohio, USA
  4. 4Department of Anatomy and Department of Surgery, Cleveland Clinic Lerner College of Medicine of Case Western Reserve University, Cleveland Clinic, Cleveland, Ohio, USA
  5. 5Department of Anesthesiology, Perioperative and Pain Medicine, Stanford University, Palo Alto, California, USA
  1. Correspondence to Dr Ban C H Tsui, Anesthesiology, Perioperative and Pain Medicine, Stanford University, Palo Alto, CA 94305, USA; bantsui{at}stanford.edu

Abstract

Background Cervical erector spinae plane (ESP) block has been described to anesthetize the brachial plexus (BP), however, the mechanism of its clinical effect remains unknown. As the prevertebral fascia encloses the phrenic nerves, BP and erector spinae muscles to form a prevertebral compartment, a local anesthetic injected in the cervical ESP could potentially spread throughout the prevertebral compartment. This study utilizes cadaveric models to evaluate the spread of ESP injections at the C6 and C7 levels to determine whether the injection can reach the BP and its surrounding structures.

Methods For each of the five cadavers, an ESP injection posterior to the transverse process of C6 was performed on one side, and an ESP injection posterior to the transverse process of C7 was performed on the contralateral side. Injections were performed under ultrasound guidance and consisted of a 20 mL mixture of 18 mL water and 2 mL India ink. After cadaver dissection, craniocaudal and medial-lateral extent of the dye spread in relation to musculoskeletal anatomy as well as direct staining relevant nerves was recorded. The degree of dye staining was categorized as “deep,” “faint,” or “no.”

Results The phrenic nerve was deeply stained in 1 injection and faintly stained in 2 injections. Caudally, variable staining of C8 (100%) and T1 (50%) roots were seen. Faintly staining at C4 root was only seen in one sample (10%). There was variable staining of the anterior scalene muscles (40%) anterior to the BP and the rhomboid intercostal plane caudally (30%).

Conclusions Ultrasound-guided cervical (C6 and C7) ESP injections consistently stain the roots of the BP and dorsal rami. This study supports the notion that the cervical ESP block has the potential to provide analgesia for patients undergoing shoulder and cervical spine surgeries.

  • brachial plexus
  • upper extremity
  • anatomy

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • Twitter @kaohesham

  • Correction notice This article has been corrected since it published Online First. Data within the article abstract and content has been corrected.

  • Contributors HE: conceived, planned, supervised, contributed, collected data, revised, approved, and is accountable for the final manuscript. RLD: collected data, contributed, revised, approved, and is accountable for the final manuscript. II and HH: collected data, contributed, approved, and is accountable for the final manuscript. BCHT: conceived, data analyses, revised, approved, and is accountable for the final manuscript.

  • Funding The authors have not declared a specific grant for this research from any funding agency in the public, commercial or not-for-profit sectors.

  • Competing interests HE has received unrestricted educational funding from PAJUNK (GA, USA), and consultant for PACIRA (Troy Hills, NJ, USA). Those companies had no input into any aspect of the present project design or manuscript preparation.

  • Patient consent for publication Not required.

  • Provenance and peer review Not commissioned; externally peer reviewed.