Unintentional Subdural Placement of Epidural Catheters During Attempted Epidural Anesthesia: An Anatomic Study of Spinal Subdural Compartment
  1. Miguel Angel Reina, MD, PhD*,,
  2. Clive B. Collier, MD,
  3. Alberto Prats-Galino, MD, PhD§,
  4. Anna Puigdellívol-Sánchez, MD, PhD§,
  5. Fabiola Machés, MD*, and
  6. José Antonio De Andrés, MD, PhD
  1. From the *Department of Clinical Medical Sciences and Applied Molecular Medicine Institute, CEU San Pablo University School of Medicine;
  2. Department of Anesthesiology, Madrid-Montepríncipe University Hospital, Madrid, Spain;
  3. Anaesthesia, Prince of Wales Private Hospital, Sydney, Australia;
  4. §Laboratory of Surgical NeuroAnatomy, Human Anatomy and Embryology Unit, Faculty of Medicine, Universitat de Barcelona, Barcelona; and
  5. Anesthesia, Critical Care and Multidisciplinary Pain Management Department, General University Hospital, Valencia, Spain.
  1. Address correspondence to: Miguel Angel Reina, MD, PhD, Department of Clinical Medical Sciences and Applied Molecular Medicine Institute, CEU San Pablo University School of Medicine; and Department of Anesthesiology, Madrid-Montepríncipe University Hospital, Madrid, Spain. c/Valmojado 95 1° B 28047 Madrid, Spain (e-mail: miguelangel.rei{at}terra.es).

Abstract

Background: Although infrequent, subdural block is a complication of epidural anesthesia with obvious implications. Knowledge of the spinal subdural compartment (dura-arachnoid interface) may help elucidate controversies arising from evidence that subdural catheter placement is feasible and may be difficult to identify clinically.

Methods: Samples of arachnoid lamina obtained during in vivo lumbosacral surgery (n = 4) and from cadavers (n = 6) were obtained and prepared for transmission electron microscopy and scanning electron microscopy. Subdural spaces were artificially produced in suitable samples, and an epidural catheter was inserted between the arachnoid and dura to compare the dimensions of meninges in relation to epidural catheters.

Results: Scanning electron microscopy of the dural sac showed areas of continuity between the arachnoid lamina and dura mater and other parts with both membranes separated by a subdural space. Transmission electron microscopy allowed the study of such border zones, where alternating cellular and collagen layers could be seen. A layer rich in collagen fibers and some fibroblasts separated arachnoid and neurothelial cells (dural border cells). Few specialized membrane junctions were found among cells adjacent to collagen fibers.

Dura mater had an average thickness of 260 to 400 μm, with a dural lamina of approximately 4 to 6 μm. In areas where the arachnoid appeared separated from the dural lamina, its thickness measured 35 to 45 μm. Catheters with a diameter of 700 μm were successfully inserted inside the subdural space, between the dura mater and the arachnoid lamina.

Conclusions: Dura mater and arachnoid layers act as a single unit but may be pulled apart by traction forces during cadaver processing of the dural sac or in vivo placement of catheters. This generates subdural spaces, either parallel or concentric, because of the minimal resistance offered by the tissue, which may be explained by its few specialized membrane junctions.

Statistics from Altmetric.com

Request Permissions

If you wish to reuse any or all of this article please use the link below which will take you to the Copyright Clearance Center’s RightsLink service. You will be able to get a quick price and instant permission to reuse the content in many different ways.

Footnotes

  • The authors have no conflict of interest to declare.